banner
Products
We pride ourselves on offering top-notch merchandise, prompt shipping, and attentive customer care.
Ce Fda/510k Mdsap Approval David Oem Medical Supply David One Step Rapid Pregnancy Test

Ce Fda/510k Mdsap Approval David Oem Medical Supply David One Step Rapid Pregnancy Test

The One Step HCG test is a rapid test to detect the presence of HCG in urine or serum specimens in a qualitative format ;
Basic Info.
Model NO. RH-HCG
Shelf Time 24-36 Month
Accuracy More Than 99%
Sensitivity 10 Miu/Ml;15miu/Ml;25miu/Ml
Specification 4.0mm/6.0. mm
Trademark DAVID, RUNBIO, OEM
Origin Shantou, China
Production Capacity 400000 Piece/Pieces Per Day
Product Description

The One Step HCG test is a rapid test to detect the presence of HCG in urine or serum specimens in a qualitative format sensitive to 15mIU HCG/ml. The test utilizes a combination of monoclonal and polyclonal antibody reagents to selectively detect elevated level of HCG in urine or serum. The immunological specificity of the test virtually eliminates cross reactivity interferences from the structurally related glycoprotein hormones hFSH, hLh, hTSH at physiological levels.

Key Features:

Easy to use
Easy to read
Able to test any time of day
Detect pregnancy as early as 1 day after the missed period
Room temperature storage

Specifications:
1) Specimen: urine; serum/urine
2) Format: strip, cassette, midstream
3) Sensitivity: 15mIU/mL
4) One kit includes 1 test (with desiccant) in a foil pouch

Ce Fda/510k Mdsap Approval David Oem Medical Supply David One Step Rapid Pregnancy Test


Ce Fda/510k Mdsap Approval David Oem Medical Supply David One Step Rapid Pregnancy Test


Ce Fda/510k Mdsap Approval David Oem Medical Supply David One Step Rapid Pregnancy Test

Ce Fda/510k Mdsap Approval David Oem Medical Supply David One Step Rapid Pregnancy Test


Ce Fda/510k Mdsap Approval David Oem Medical Supply David One Step Rapid Pregnancy Test

Test Method

Strip

(1) Remove the device from the sealed pouch.

(2) With arrows pointing toward the urine sample, immerse the device vertically in the urine sample for at least 10 seconds.

(3) Start timing and observe the result within 5-10 minutes.

Cassette

(1) Remove the device from the sealed pouch and lay it on a flat surface.

(2) Take out the dropper provided with the device, draw urine and then continuously add 2-3 drops into the sample well.

(3) Start timing and observe the result within 5-10 minutes. Midstream

(1) Remove the device from the sealed pouch.

(2) Hold the handle of the device, take off the cap (if any), then directly urinate towards the absorbent tip for 2-3s. After that put on the cap (if any) and lay the device on a flat surface or keep holding it flat. The alternative method is that hold the handle of the device, take off the cap (if any), immerse the device vertically in the urine sample for at least 10 seconds. Remove the device from urine sample and lay it on a flat surface or keep holding it.

(3) Start timing and observe the result within 5-10 minutes.

Interpretation

of Results

Positive: One red line appears in the test region (T) and another red line appears in the control region (C).

Negative: A red line appears in the control region (C) but no red line appears in the test region (T).

Invalid:No line in both the test region (T) and control region (C), or a red line appears in the test region (T) but no red line appears in the control region (C).


Send inquiry